[May 22, 2024] Free VMware Specialist 5V0-35.21 Exam Question
5V0-35.21 dumps & VMware Specialist sure practice dumps
VMware 5V0-35.21 certification exam is designed for IT professionals who are interested in obtaining a specialty certification in VMware vRealize Operations. VMware vRealize Operations Specialist certification exam measures the individual's knowledge and skills in deploying, configuring, and managing VMware vRealize Operations. It is an industry-recognized certification that certifies the individual's ability to monitor and troubleshoot complex virtual environments.
NEW QUESTION # 60
An administrator is working on capacity forecasting in a virtualization infrastructure that is optimized with vRealize Operations. The VM rightsizing operations are completed with undersized and oversized virtual machine reports, but the virtualization infrastructure is still running out of capacity in less than 90 days.
The administrator decides to examine the recommendations in Capacity Optimization Overview in order to solve the problem.
Which three recommendations are possible in this situation? (Choose three.)
- A. Add CPU
- B. Increase VM CPU
- C. Add Disk Space
- D. Decrease VM CPU
- E. Decrease VM Memory
- F. Add Memory
Answer: A,C,F
Explanation:
vRealize Operations can make recommendations for increasing time remaining based on the data it receives and these recommendations appear at the bottom of the Capacity Optimization Overview screen. You might see two options: Option 1 shows what you can achieve by reclaiming resources. Option 2 shows the results of adding capacity1. The recommendations for adding capacity depend on which resource is the most constrained in the cluster. For example, if the cluster is running out of memory, the recommendation might be to add memory to the existing hosts or add new hosts with sufficient memory. Similarly, if the cluster is running out of CPU or disk space, the recommendation might be to add CPU or disk space to the existing hosts or add new hosts with sufficientCPU or disk space2. Therefore, the possible recommendations for adding capacity in this situation are B.
Add Memory, C. Add CPU, and F. Add Disk Space. The other options, A. Decrease VM Memory, D. Increase VM CPU, and E. Decrease VM CPU, are not valid recommendations for adding capacity, as they are related to reclaiming resources or rightsizing VMs. References: 1: Optimize Capacity - VMware Docs(https://docs.vmware.com/en/vRealize-Operations/8.10/com.vmware.vcom.user.doc/GUID-62358711-BEA Add Capacity - VMware Docs(https://docs.vmware.com/en/vRealize-Operations/8.10/com.vmware.vcom.core.doc/GUID-52C3F7EA-2E2
NEW QUESTION # 61
An administrator created a new cost-based pricing card and attached it to a VMware Cloud on AWS (VMC) resource. When the administrator checked the pricing of a VM after the cost calculation had successfully run, the pricing showed zero.
What is the possible reason for this situation?
- A. Pricing cards are not supported with VMC resources.
- B. Only rate-based pricing cards are applied with VMC.
- C. A zero value was used for one of the Basic Charges in the pricing card.
- D. The cost calculation needs to run twice, when using VMC.
Answer: B
Explanation:
The possible reason for this situation is that only rate-based pricing cards are applied with VMC resources. A rate-based pricing card is a pricing card that defines the rates for each resource type, such as CPU, memory, disk, and network. A cost-based pricing card is a pricing card that defines the basic charges for each object type, such as host, cluster, datastore, and virtual machine. vRealize Operations supports both types of pricing cards for vSphere resources, but only supports rate-based pricing cards for VMC resources1. When a cost-based pricing card is assigned to a VMC resource, the price calculated for the policy is reported as zero2.
To avoid this situation, the administrator should create and assign a rate-based pricing card for the VMC resource.
The other options are not correct, because they are not the possible reasons for this situation. Option A is not correct, because a zero value for one of the basic charges in the cost-based pricing card would not result in a zero price for the VM. The price of the VM would be calculated based on the sum of the basic charges for the VM object type and its parent object types, such as datastore, cluster, and host3. Option C is not correct, because the cost calculation does not need to run twice when using VMC. The cost calculation runs every 24 hours for all the pricing cards, regardless of the cloud provider4. Option D is not correct, because pricing cards are supported with VMC resources, as long as they are rate-based pricing cards1.
References:
Pricing for vRealize Automation 8.x Components in vRealize Operations - VMware Docs Pricing Overview - VMware Docs Add New Pricing Card - VMware Docs Cost Calculation - VMware Docs
NEW QUESTION # 62
After deploying vRealize Operations, an administrator needs to configure cost drivers to accurately reflect the purchase price and date of all nodes within the VMware vSAN cluster that are being monitored.
Which type of cost driver should the administrator select?
- A. Server Hardware: Traditional
- B. Server Hardware: Hyper-Converged
- C. Additional Costs
- D. Storage
Answer: B
NEW QUESTION # 63
An administrator configured a Symptom with a Wait Cycle of 3 and a Cancel Cycle of 2. The default cycle was not changed.
How many minutes will it take for both to be triggered?
- A. Wait: 15 minutes, Cancel: 20 minutes
- B. Wait: 20 minutes, Cancel: 15 minutes
- C. Wait: 15 minutes, Cancel: 10 minutes
- D. Wait: 15 minutes, Cancel: 15 minutes
Answer: C
Explanation:
According to the VMware vRealize Operations Reference Materials, the Wait Cycle and the Cancel Cycle are the settings that determine how long a symptom condition must be true or false before the symptom is triggered or cancelled. The default cycle for both settings is 5 minutes, which means that each cycle corresponds to one collection interval of 5 minutes. Therefore, if a symptom has a Wait Cycle of 3 and a Cancel Cycle of 2, it will take 15 minutes (3 cycles x 5 minutes) for the symptom to be triggered after the condition becomes true, and 10 minutes (2 cycles x 5 minutes) for the symptom to be cancelled after the condition becomes false. The other options are incorrect because they do not match the calculation based on the given settings and the default cycle. References: Symptom Definition Settings; Alert Definition Best Practices
NEW QUESTION # 64
During an upgrade of the vRealize Operations cluster via the Administration UI, the cluster has failed, and the status has changed to offline.
Which remediation strategy should be used to manage this problem and continue the installation process?
- A. Manually bring the cluster online, and then select Finish Installation.
- B. Manually take the cluster offline, and then select Rollback Installation.
- C. Manually take the cluster offline, and then select Finish Installation.
- D. Manually bring the cluster online, and then select Rollback Installation.
Answer: A
Explanation:
According to the VMware vRealize Operations Install and Configure Guide1, when upgrading the vRealize Operations cluster via the Administration UI, the cluster status should change from offline to online after the upgrade process is completed. However, if the cluster status remains offline or fails during the upgrade, the administrator can use the Finish Installation option to resume the upgrade process. The Finish Installation option attempts to bring the cluster online and complete the upgrade. The administrator can monitor the progress of the upgrade from the Administration UI or the Cluster Management page.
The other options are not suitable for managing this problem and continuing the installation process. The Rollback Installation option is used to revert the cluster to the previous version of vRealize Operations, not to resume the upgrade process. The Rollback Installation option is only available if the cluster is online and the upgrade has failed. The administrator should not manually take the cluster offline, as this would interrupt the upgrade process and cause data loss or corruption. References:
1: VMware vRealize Operations Install and Configure Guide,
https://docs.vmware.com/en/vRealize-Operations/8.5/vrealize-operations-manager-85-installation-and-con page 54-55, 58-59
NEW QUESTION # 65
An administrator is planning the size of a new vRealize Operations Manager (vROps) platform using the vROps sizing tool. The output of different configurations and sizing information from the tool were modeled for internal design discussion.
Refer to the exhibit:
Which configuration was sized?
- A. Stretched Cluster
- B. High Availability
- C. Fault Tolerance
- D. Continuous Availability
Answer: A
NEW QUESTION # 66
The VMware Cloud Director administrator wants to make sure that the system is able to collect log bundles from all cells at once.
How should the administrator accomplish this goal?
- A. Configure a syslog server on each of the cells, and request the logs from the syslog server.
- B. Install vRealize Log Insight agent on each cell to redirect logs to a centralized location.
- C. Make sure the NFS server allows read-write access to the shared location by the root system account on each cell.
- D. Map the log location on the primary cell to a shared folder on each of the other cells in the server group, ensuring they all have read/write rights on the primary.
Answer: C
Explanation:
Making sure the NFS server allows read-write access to the shared location by the root system account on each cell is the correct way to enable the collection of log bundles from all cells at once. This is because VMware Cloud Director uses the vmware-vcd-support script to collect host log information as well as Cloud Director logs, and this script requires the NFS server to have read-write access to the shared location by the root system account on each cell1. Installing vRealize Log Insight agent on each cell to redirect logs to a centralized location is not a valid option, as vRealize Log Insight is a separate product that does not integrate with VMware Cloud Director. Configuring a syslog server on each of the cells, and requesting the logs from the syslog server is not a feasible option, as it would require manual intervention and coordination to collect the logs from multiple sources. Mapping the log location on the primary cell to a shared folder on each of the other cells in the server group, ensuring they all have read/write rights on the primary is not asufficient option, as it does not address the NFS server configuration that is required for the vmware-vcd-support script to work properly. References: Collecting diagnostic information for VMware Cloud Director (1026312). Preparing the Transfer Server Storage for VMware Cloud Director on Linux.
NEW QUESTION # 67
Which three details can be configured when creating a custom view? (Choose three.)
- A. Format
- B. Custom View Tag
- C. Data
- D. Presentation
- E. Input Transformation
- F. Subject
Answer: A,B,C
NEW QUESTION # 68
An administrator has been tasked with configuring service discovery to identify which virtual machines are running Active Directory services. All virtual machines are running on vSphere 6.5.
Which credentials, if any, are needed for the administrator to complete this task?
- A. Local Windows administrator account and password.
- B. No credentials are needed since credential-less service discovery can be used.
- C. Active Directory domain user account and password.
- D. Active Directory domain administrator account and password.
Answer: D
NEW QUESTION # 69
What are the two required components of an alert definition? (Choose two.)
- A. Version
- B. Recommendation
- C. Action
- D. Node
- E. Symptom
Answer: C,E
NEW QUESTION # 70
Which two are supported Cloud Account types in vRealize Operations? (Choose two.)
- A. Horizon Connection Server
- B. vRealize Automation
- C. Microsoft Azure
- D. vCenter Server
- E. Google Cloud Platform
Answer: B,E
NEW QUESTION # 71
An administrator is using vRealize Operations to optimize capacity within a vSphere Datacenter. The administrator will use the main categories for reclamation that are shown under the Reclaim view on the Home Screen navigation.
Which three main categories are available to the administrator in this view? (Choose three.)
- A. Powered Off VMs
- B. Snapshots
- C. Orphaned Disks
- D. Unused Hosts
- E. VM Disks utilized %10 or less
- F. Unused Datastores
Answer: C,E,F
NEW QUESTION # 72
A customer wants to monitor a remote datacenter using an existing vRealize Operations Manager cluster. The round-trip time (RTT) between datacenters is 150 ms.
Which type of node should be deployed?
- A. Data node
- B. IRemote Collector node
- C. Replica node
- D. witness node
Answer: B
Explanation:
The type of node that should be deployed to monitor a remote datacenter using an existing vRealize Operations Manager cluster is a Remote Collector node. A Remote Collector node is a node that is deployed in a remote datacenter location across a firewall, and collects data from the remote objects without performing analysis or storing data. A Remote Collector node can reduce the bandwidth consumption and the load on the vRealize Operations analytics cluster, and can also navigate firewalls and interface with remote data sources12. A Remote Collector node can be deployed on a different operating system than the rest of the cluster, and can support a round-trip time (RTT) of up to 200 ms3.
The other options are not correct, because they are not suitable for monitoring a remote datacenter with a high RTT. A Replica node is a node that is converted from a Data node to provide high availability (HA) or continuous availability (CA) for the vRealize Operations cluster. A Replica node is a copy of the Primary node, and must be deployed in the same datacenter as the Primary node1. A Data node is a node that performs data collection and analysis for the vRealize Operations cluster, and can be added to scale out the cluster capacity and performance. A Data node must be deployed in the same datacenter as the Primary node, and can support a RTT of up to 10 ms1. A Witness node is a node that is required for continuous availability (CA) of the vRealize Operations cluster, and acts as a decision maker in case of a network partition between two fault domains. A Witness node must be deployed in a third datacenter that is separate from the two fault domains, and can support a RTT of up to 100 ms1.
References:
About vRealize Operations Cluster Nodes - VMware Docs
vRealize Operations Manager: Design Introduction - VMware Blogs
Mastering vRealize Operations Manager - Second Edition - Packt Subscription vRealize Operations node types - Mastering vRealize Operations Manager ...
NEW QUESTION # 73
Which two Remote Checks are available in vRealize Operations to manage Telegraf Agents on a virtual machine? (Choose two.)
- A. RDP
- B. FTP
- C. ICMP
- D. TCP
- E. SMTP
Answer: C,D
Explanation:
Remote Checks are a type of Telegraf plugin that allow you to monitor the availability and performance of remote services or endpoints from the Telegraf agent installed on a virtual machine. You can configure Remote Checks from the Manage Telegraf Agents page in vRealize Operations. There are two types of Remote Checks available: ICMP and TCP. ICMP (Internet Control Message Protocol) checks use ping commands to test the connectivity and response time of a target IP address or hostname. TCP (Transmission Control Protocol) checks use socket connections to test the connectivity and response time of a target IP address or hostname and port number. SMTP (Simple Mail Transfer Protocol), FTP (File Transfer Protocol), and RDP (Remote Desktop Protocol) are not Remote Checks, but they are Application Services that can be discovered and monitored by the Telegraf agent using other plugins. References:
Additional Operations from the Manage Telegraf Agents Page
Telegraf Agent Remote Check
Checking SSL/TLS Certificate Validity Period using vRealize Operations Application Monitoring Automating App Monitoring vRealize-Automated-Install-of-Telegraf-Agent
NEW QUESTION # 74
Within a large enterprise IT department, a member of the monitoring team has moved to another role within the operations team. The administrator's user account was initially assigned the PowerUserMinusRemediation role, but the PowerUser role has now been added by the helpdesk team following the job change.
Which statement accurately describes the nature of this change?
- A. The administrator will now be able to perform cluster management tasks but unable to complete remediation actions.
- B. The administrator will now be able to complete tasks associated with remediation actions.
- C. The administrator will remain unable to complete tasks associated with remediation actions.
- D. The administrator will now be able to perform user management tasks and remediation actions.
Answer: B
Explanation:
The nature of this change is that the administrator will now be able to complete tasks associated with remediation actions, such as executing actions on alerts, recommendations, or symptoms. This is because the PowerUser role includes all the privileges of the PowerUserMinusRemediation role, plus the privileges to perform remediation actions. The PowerUserMinusRemediation role is a predefined role that has all the privileges of the Administrator role except for user management, cluster management, and remediation actions. The PowerUser role is a predefined role that has all the privileges of the Administrator role except for user management and cluster management. Therefore, by adding the PowerUser role to the administrator's user account, the helpdesk team has granted the administrator the additional privilege to perform remediation actions. The administrator will not be able to perform cluster management tasks or user management tasks, as these privileges are not included in the PowerUser role or the PowerUserMinusRemediation role. The administrator will not remain unable to complete tasks associated with remediation actions, as this privilege is included in the PowerUser role. References: Roles and Privileges in vRealize Operations, section "Roles and Privileges in vRealize Operations". vRealize Operations Manager User Guide, section "Create and Configure Dashboards".
NEW QUESTION # 75
An administrator wants to configure vRealize Operations to operate in Continuous Availability mode for resiliency. The administrator has deployed all required nodes, registered the nodes as members of the vRealize Operations cluster, and must now configure the Continuous Availability mode.
How should this configuration be completed?
- A. The administration User Interface -> Architecture -> Configure Availability
- B. The product User Interface -> Administration -> Support -> Configure Availability
- C. The administration User Interface --> System Status --> Configure Availability
- D. The product User Interface -> Administration -> Cluster Management -> Configure Availability
Answer: D
Explanation:
To configure vRealize Operations to operate in Continuous Availability mode, you need to use the product User Interface -> Administration -> Cluster Management -> Configure Availability option. This option allows you to enable or disable Continuous Availability for the vRealize Operations cluster, as well as to view and edit the fault domains and node pairs. You can also monitor the status and synchronization of the nodes in each fault domain12. The other options are not correct because:
The administration User Interface --> System Status --> Configure Availability option does not exist. The administration User Interface only has the following tabs: System Status, Cluster Management, Software Update, and Support3.
The administration User Interface -> Architecture -> Configure Availability option does not exist. The administration User Interface does not have an Architecture tab3.
The product User Interface -> Administration -> Support -> Configure Availability option does not exist. The Support tab under the Administration menu only has the following options: Logs, Support Bundles, and Support Alerts4. References: 1: Enable Continuous Availability in vRealize Operations 2: About vRealize Operations Continuous Availability 3: [vRealize Operations Manager Administration Interface] 4: [Support]
NEW QUESTION # 76
......
To prepare for the VMware vRealize Operations Specialist exam, candidates should have hands-on experience with vRealize Operations and should take advantage of the resources available from VMware. VMware offers a range of training courses and study materials, including online courses, practice exams, and study guides. Candidates can also participate in the VMware Learning Zone, which provides access to expert instructors and interactive training sessions. With the right preparation and study, candidates can pass the VMware vRealize Operations Specialist exam and earn a valuable certification that can enhance their career prospects in the IT industry.
VMware 5V0-35.21 Actual Questions and Braindumps: https://www.examstorrent.com/5V0-35.21-exam-dumps-torrent.html
Pass 5V0-35.21 Exam with Updated 5V0-35.21 Exam Dumps PDF 2024: https://drive.google.com/open?id=1S8wYvTuv_Q2Q8XHjVq8y-Fpl8qVabt4i